Air-cooled condenser with a V-form finned coil block, top-mounted fans and copper return bends
Heat Exchange

Heat Exchange

Air-Cooled Condensers

Heat rejection where water is scarce or treatment is impractical, sized against Saudi ambient rather than a temperate design day.

Part of our Air-Cooled Condensers service line — we supply, install and maintain it, not just sell it.

Overview

What it does.

An air-cooled condenser trades water for air and surface area. There is no basin, no bleed, no dosing and no legionella management — and in return the unit is larger, the fans draw more, and the condensing temperature follows dry bulb rather than wet bulb.

Sizing is where these are usually got wrong. A unit rated at 35 °C ambient is not a unit rated for a Jeddah afternoon, and the shortfall shows up as high head pressure and tripped compressors in exactly the weeks the plant matters most.

Coil face, fin spacing and fan selection are chosen for the site. Wider fin spacing costs surface area but survives dust; that is a trade worth making deliberately rather than by default.

Gallery

Representative units and components. Configuration, finish and connection sizes are built to the order — these show the range, not a fixed model.

Air-cooled condenser with twin axial fans on the end face and a finned coil block behind the frame
Fan face and coil block
Galvanised air-cooled condenser frame with copper return bends running down the open coil end
Return bends at the coil end
Air-cooled condenser viewed along the V-form coil, with the bracing frame and headers in the foreground
V-form coil arrangement
Tall air-cooled condenser bank with fans across the top deck and coils on both long faces
Multi-fan bank
Close view of a condenser coil face with copper headers and the fan guard beyond
Coil face and copper headers
Specification

The numbers.

Sizes, materials and duty are confirmed against your drawing and a site survey before quotation — nothing here is a fixed catalogue entry.

Technical

Air-Cooled Condensers specification
Heat rejection50 – 1,500 kW per unit
ConfigurationV-form, flat or vertical coil
FansAxial, direct drive, VFD compatible
Design ambientSelected to site, typically 45 – 50 °C
Fin spacing2.1 – 3.2 mmWider for dusty sites

Indicative figures. Final specification is confirmed against your duty and site survey at quotation.

Materials of construction

Air-Cooled Condensers materials
TubesCopper
FinsAluminium, epoxy-coated option
FrameHot-dip galvanised steel
HeadersCopper with brazed joints
Selection

Where it fits.

Applications

  • Refrigeration plant on water-scarce sites
  • Process condensing in remote locations
  • Chiller replacement where a tower is not permitted
  • Standby condensing capacity

Options & accessories

Epoxy or hydrophilic coated fins for coastal airEC fans and speed controlAdiabatic pre-cooling for peak ambientCoil guards and hail protection
Same category

More heat exchange equipment.

Stainless shell and tube heat exchanger with the channel head removed, exposing the copper tube bundle and tubesheet

Shell & Tube Heat Exchangers

Shell and tube exchangers built to duty — copper, cupro-nickel or stainless bundles in carbon or stainless shells, sized against the process rather than a catalogue rating and pressure tested before despatch.

View product
Dry cooler with twin axial fans on the end face, a finned coil and copper return bends in a galvanised frame

Dry Coolers

Dry coolers for closed-loop process and comfort cooling — heat rejected to ambient with no evaporative loss, no make-up water and no water treatment to maintain.

View product
Industrial radiator core in a steel frame with flanged connections on both sides and a copper finned matrix

Process Radiators

Finned-tube radiators and cooling blocks for engine, generator and process duty. Built to the existing core dimensions so a replacement drops into the frame the old one came out of.

View product

Ready to start?

Breakdown response and planned maintenance, Kingdom-wide

Seven service lines. One engineering team. Tell us your load, site and timeline — we will come back with a costed proposal.