Service 04 · Design, Supply, Install & Commission
HVAC & MEP
Mechanical, electrical and plumbing engineering for commercial and industrial facilities — from load calculation and system design through installation, commissioning and handover.

How we approach it.
Full-scope MEP means one team carries the job from load calculation to handover, so the ductwork suits the AHU, the electrical supply suits the plant, and nobody is negotiating an interface between three subcontractors halfway through the programme.
Design starts with a real load calculation — envelope, occupancy, process gains, fresh air requirement — because a system sized from a rule of thumb is either short of capacity on the peak day or oversized and cycling for the rest of the year.
We commission properly: airflows balanced and recorded, water side proportionally balanced, controls proven through their sequences, and an O&M package that someone can actually operate the building from.
Included in scope
- Load calculation & design
- Equipment procurement
- Full installation
- Commissioning & handover
The work, as it runs.
Plant we have installed and equipment we have had apart — photographed on the shop floor and on site, not staged.





What we can build to.
Ranges below cover the majority of what we make. Duties outside them are reviewed case by case rather than refused on principle.
| Scope | Design, supply, install, commission, handover |
|---|---|
| Load calculation | Full envelope, occupancy and process gain analysis |
| Ductwork | Galvanised rectangular and round spiral, fabricated to drawing |
| Chilled water | Primary/secondary, variable primary, DX split systems |
| Controls | Standalone and BMS-integrated |
| Balancing | Air and water side, recorded and certified |
Indicative figures. Final specification is confirmed against your duty and site survey at quotation.
Standards & testing
- ASHRAE design methodology
- SMACNA duct construction practice
- Air and water balancing recorded and certified
How the work runs.
The same sequence every time, so you know what happens next and what is expected of you at each stage.
- 01
Load calculation & design
Cooling and heating loads calculated from the building, not estimated from floor area. Equipment selected against the result.
- 02
Drawings & approvals
Layouts, schematics and equipment schedules issued for approval and coordinated against structure and other services.
- 03
Procurement
Plant and materials procured against the approved schedule, with delivery sequenced to the site programme.
- 04
Installation
Ductwork, pipework, plant and electrical installed by our own teams, with progressive inspection rather than one inspection at the end.
- 05
Commissioning & handover
Airflows and water flows balanced and recorded, control sequences proven, O&M documentation and operator training delivered.
Where it is used.
Parts and plant for this line.
Asked before you ask.
Will you take on design-and-build, or only install to someone else’s design?
Both. We are happy to install to a consultant’s design, and equally happy to take the design responsibility. If we are installing to a design we think is wrong, we will raise it in writing before starting rather than after.
Do you work on occupied buildings?
Yes. Phased work in live buildings is routine — it mainly changes the programme and the out-of-hours content, both of which we price openly rather than as variations later.
What does handover include?
Balancing records, commissioning sheets, as-built drawings, equipment documentation and operator training. If your facilities team cannot run the building from what we hand over, the handover is not finished.
Other service lines.

Shell & Tube Heat Exchanger
Custom-engineered shell and tube heat exchangers for process industries — from initial thermal design through precision fabrication, pressure testing, and field re-tubing of existing units.
Read more
Evaporative Condensers
Evaporative condensers and closed-circuit cooling towers for refrigeration systems, process cooling, and industrial applications requiring efficient heat rejection with minimal water consumption.
Read more
Air-Cooled Condensers
Air-cooled heat rejection equipment for applications where water availability is limited — from process radiators and dry coolers to refrigeration evaporators and industrial condensers.
Read moreReady to start?
Breakdown response and planned maintenance, Kingdom-wide
Seven service lines. One engineering team. Tell us your load, site and timeline — we will come back with a costed proposal.