Shell-and-tube and plate evaporators matched to refrigerant, approach and the fouling the fluid will actually carry.

Part of our Air-Cooled Condensers service line — we supply, install and maintain it, not just sell it.

Overview

What it does.

The evaporator is where a refrigeration plant either makes its duty or quietly does not. Undersize it and the suction pressure sits low, the compressor runs longer than it should, and the running cost of that decision is paid every day for the life of the plant.

Selection is against refrigerant, approach temperature and fouling factor together. A clean-water duty and a process duty carrying solids need different tube velocities and different cleaning access, even at identical kilowatts.

We supply both shell-and-tube and plate types, and will say which one the duty actually wants — plates are compact and efficient until the fluid fouls them, at which point a shell that opens is worth more than the floor space it costs.

Gallery

Representative units and components. Configuration, finish and connection sizes are built to the order — these show the range, not a fixed model.

Stainless evaporator shell on a skid frame with the copper tube bundle visible through the open end
Shell and tube bundle
Compact evaporator vessel with copper tubes, flanged nozzles and pressure gauges on the connecting pipework
Nozzles and instrument tappings
Large evaporator with the tubesheet exposed at the open end, showing the full tube pattern
Tubesheet exposed
Plate-pack evaporator in a stainless frame with pipework rising to the top connections
Plate pack and risers
Evaporator plate pack mounted on a base tank with flanged side connections and a nameplate
Pack on a base tank
Vertical evaporator columns connected by copper pipework, with gauges and isolating valves
Vertical column arrangement
Tall evaporator vessel in a stainless frame with multiple flanged branches around the shell
Framed vessel with branches
Specification

The numbers.

Sizes, materials and duty are confirmed against your drawing and a site survey before quotation — nothing here is a fixed catalogue entry.

Technical

Evaporators specification
Duty20 – 1,200 kW
TypeFlooded, DX shell-and-tube, or plate
RefrigerantsAmmonia, HFC and HFO blends
Design pressureUp to 25 bar refrigerant side
Approach2 – 6 K, to duty

Indicative figures. Final specification is confirmed against your duty and site survey at quotation.

Materials of construction

Evaporators materials
TubesCopper, stainless or cupro-nickel
ShellCarbon steel or stainless
PlatesStainless 316, brazed or gasketed
InsulationClosed-cell, vapour sealed
Selection

Where it fits.

Applications

  • Chilled water generation
  • Process fluid and brine cooling
  • Cold storage and blast freezing
  • Beverage and dairy chilling

Options & accessories

Gasketed plate pack for cleaning accessMarine heads for tube-side inspectionFactory insulation and claddingWitnessed pressure testing
Same category

More heat exchange equipment.

Stainless shell and tube heat exchanger with the channel head removed, exposing the copper tube bundle and tubesheet

Shell & Tube Heat Exchangers

Shell and tube exchangers built to duty — copper, cupro-nickel or stainless bundles in carbon or stainless shells, sized against the process rather than a catalogue rating and pressure tested before despatch.

View product
Air-cooled condenser with a V-form finned coil block, top-mounted fans and copper return bends

Air-Cooled Condensers

Air-cooled condensers for sites where water is scarce or treatment is impractical. Coil face and fan selection are sized against Saudi summer ambient, not a temperate design day.

View product
Dry cooler with twin axial fans on the end face, a finned coil and copper return bends in a galvanised frame

Dry Coolers

Dry coolers for closed-loop process and comfort cooling — heat rejected to ambient with no evaporative loss, no make-up water and no water treatment to maintain.

View product

Ready to start?

Breakdown response and planned maintenance, Kingdom-wide

Seven service lines. One engineering team. Tell us your load, site and timeline — we will come back with a costed proposal.